歡迎光臨深圳市鑫博恒業(yè)科技有限公司網(wǎng)站!
全國服務(wù)咨詢熱線:

13823144468

產(chǎn)品展示 / products 您的位置:網(wǎng)站首頁 > 產(chǎn)品展示 > > 美國omega壓力傳感器 > DPG1000ADA-100G-2N壓力表 美國omega

DPG1000ADA-100G-2N壓力表 美國omega

簡要描述:DPG1000ADA-100G-2N壓力表 美國omega, 一手貨源,優(yōu)勢批發(fā),精度高,是優(yōu)質(zhì)的壓力傳感器

  • 產(chǎn)品型號:
  • 廠商性質(zhì):代理商
  • 更新時間:2025-05-24
  • 訪  問  量:2215
詳情介紹

DPG1000ADA-100G-2N壓力表 美國omega

報警裝置和模擬輸出功能的數(shù)字壓力計
DPG1000ADA_DPG1000DAR系列
DPG1000ADA_DPG1000DAR 系列:報警裝置和模擬輸出功能的數(shù)字壓力計
DPG1000ADA-15G-1N
AD or DC Powered with Dual Alarms
DC Powered with Dual Alarms and Analog Output
Ranges between 15 psi and 3000 psi
Normal or Reverse Acting Alarms
Hi/Lo, Hi/Hi, or Lo/Lo Alarms available
Colored LED Alarm Status Indicators
Using the DPG1000ADA and DPG1000DAR Alarm Outputs Normal (Fail-safe) vs. Reverse Action—The convention for alarm action is that with the normal or fail-safe configuration, the alarm output relays will be CLOSED (relay energized) for a clear or non-alarm condition and OPEN (relay not energized) for an alarm condition. This is primarily for users who require an alarm condition if the gauge loses power or suffers a catastrophic failure. In the wiring diagrams, the normally closed and normally open designations refer to standard relay terminology (i.e., the relay contact status with the relay coil not energized). Therefore, with the normal (fail-safe) configuration in a green or non-alarm condition, the relay will be energized so that continuity can be expected between the common and normally open leads. In a red or alarm condition, the relay will be open (not energized) so that continuity can be expected between the common and normally closed leads.
Contact Rating and Protection The contacts of the alarm relays are rated at 1 A/24 Vdc or 0.5 A/ 115 Vac. Switching loads greater than the rating, or switching large inductive loads, will shorten the useful life of the contacts. In lowlevel switching or with dry contacts, the user should consider whether external contact protection, such as snubber networks or arc suppression networks, is required to protect the contacts. In addition, no internal fusing is included in the DPG1000 contact circuits. The circuit external to the gauge alarm outputs should be fused by the user in applications in which good design dictates this practice.
Using the DPG1000DAR Analog Output The analog output is easy to use if a few system considerations are observed. The DPG1000DAR is DC powered, with the gauge power supply (–) tied to the 4 to 20 mA (–). Therefore, the DC supply (–) lead should be considered common with regard to the analog output (–) or ground connection in the user’s system. Be sure to observe the output compliance (voltage drive) capabilities of the gauge. The compliance, and therefore the maximum loop resistance the output can drive, is a function of the supply voltage to the gauge. Consult the manual for maximum loop resistance vs. supply voltage. Too large a loop resistance will cause the gauge output to “l(fā)imit" or saturate before reaching its full 20 mA output.
DPG1000ADA AC/DC Powered with Dual Alarms
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C" (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bicolor (red/green) LEDs on front panel
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation
Alarm Response Time: 100 ms typical
Power: Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS)
DPG1000DAR DC Powered with Dual Alarms and 4 to 20 mA Output
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers analog output zero/span; internal potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C" (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bi-color (red/green) LEDs on front panel
Alarm Response Time: 100 ms typical
Analog Output: 4 to 20 mA DC; output drive (compliance) determined by power source
Analog Output Response Time: 50 ms, typical
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status and simultaneously sets display and analog output to “calibration" level, independent of pressure input, to allow testing system operation
Power: Any DC source of 9 to 32 Vdc, 1.0 W max
Electrical Connection: 0.9 m (3') long, 4-conductor 22 AWG shielded cable for power and retransmitted output; 0.9 m (3') long, 6-conductor 22 AWG cable for alarm contacts
ALARMS (final siffix 1N standard)
1 = HI/LO (standard)
2= HI/HI
3= LO/LO
N = Normal Acting (standard)
R = Reverse Acting
Example: DPG1000ANA-15G-3R HAS LO/LO ALARMS, Reverse Acting

 DPG1000ADA-100G-2N壓力表 美國omega 

相關(guān)產(chǎn)品:

DPG1000B-2KG壓力表 美國omega



留言詢價

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
技術(shù)支持:化工儀器網(wǎng)   sitemap.xml   管理登陸
© 2025 版權(quán)所有:深圳市鑫博恒業(yè)科技有限公司( www.c145.com)   備案號:粵ICP備09037369號   
主站蜘蛛池模板: 国产色在线|亚洲| www.av小四郎.com| 杨幂一级做a爰片性色毛片| 人人添人人澡人人澡人人人人| 老公说我是不是欠g了| 国产啪精品视频网站免费尤物| 两个人看www免费视频| 在线免费视频a| m.jizz4.com| 成人午夜福利视频镇东影视 | 青青草原伊人网| 国产欧美另类精品久久久| 2020国语对白露脸| 国内精品视频在线播放一区| ww4545四虎永久免费地址| 成人免费乱码大片a毛片| 久久久一本精品99久久精品66 | 国产黄色二级片| a级片免费在线观看| 婷婷综合五月天| 一级做a爰片久久毛片唾| 成人片黄网站色大片免费| 久久一区二区三区精品| 日韩亚洲人成在线综合| 乱人伦一区二区三区| 黄色福利视频网站| 国产精品无码素人福利不卡| 97精品国产高清自在线看超| 夜夜高潮夜夜爽夜夜爱爱| mm1313亚洲国产精品无码试看| 宝宝看着我是怎么进去的视频| 三级黄色录像片| 成人毛片视频免费网站观看| 中文字幕影片免费在线观看| 无套内射无矿码免费看黄| 久久99精品国产麻豆婷婷| 日本三级做a全过程在线观看| 久久人妻av无码中文专区| 日本肉体xxxx裸交| 久久国产亚洲观看| 日本成人在线免费观看|